- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Fullwood, David (1)
-
Manda, Sanjay (1)
-
Pai, Namit (1)
-
Patra, Anirban (1)
-
Samajdar, Indradev (1)
-
Sudhalkar, Bhargav (1)
-
Syphus, Bethany (1)
-
Wright, Stuart (1)
-
de_Kloe, René (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract Modern analytical tools, from microfocus X-ray diffraction (XRD) to electron microscopy-based microtexture measurements, offer exciting possibilities of diffraction-based multiscale residual strain measurements. The different techniques differ in scale and resolution, but may also yield significantly different strain values. This study, for example, clearly established that high-resolution electron backscattered diffraction (HR-EBSD) and high-resolution transmission Kikuchi diffraction (HR-TKD) [sensitive to changes in interplanar angle (Δθθ)], provide quantitatively higher residual strains than micro-Laue XRD and transmission electron microscope (TEM) based precession electron diffraction (PED) [sensitive to changes in interplanar spacing (Δdd)]. Even after correcting key known factors affecting the accuracy of HR-EBSD strain measurements, a scaling factor of ∼1.57 (between HR-EBSD and micro-Laue) emerged. We have then conducted “virtual” experiments by systematically deforming an ideal lattice by either changing an interplanar angle (α) or a lattice parameter (a). The patterns were kinematically and dynamically simulated, and corresponding strains were measured by HR-EBSD. These strains showed consistently higher values for lattice(s) distorted by α, than those altered by a. The differences in strain measurements were further emphasized by mapping identical location with HR-TKD and TEM-PED. These measurements exhibited different spatial resolution, but when scaled (with ∼1.57) provided similar lattice distortions numerically.more » « less
An official website of the United States government
